Page 0 INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR THE ROTARY TANKER PUMP

Strany 2

Page 9 2.4 Cleaning. The RTPTM pump series is suitable for both manual cleaning and CIP (Cleaning In Place), refer to section 3.3.2. The product

Strany 3

Page 10 2.5.1 Atex Information Plate 2.5.2 Equipment Groups & Catergories Category 2

Strany 4

Page 11 2.6 Pump Model and Serial Number. Should you require any information regarding your RTPTM rotary lobe pump contact JPUK or your JPUK distr

Strany 5

Page 12 3.0 General. 3.1 RTPTM Pumping Principle. The pumping action of the rotary lobe pump principle is generated by the contra-rotation of two pu

Strany 6

Page 13 3.2 RTPTM Operating Parameters. Fig 5 Operating Parameters RTP20 Theoretical Displacement Nominal Connection Size Max Diff. Pressure Maxi

Strany 7

Page 14 Be sure ample room is provided around the pump to allow for: • Access to the pump and drive for routine inspection and maintenance, i.e. to

Strany 8 - Recommended Measures

Page 15 Observing the following general guidelines should ensure the best possible suction condition is created. • Suction piping is at least the s

Strany 9

Page 16 Where motor mounted options are to be installed follow the manufactures recommended guidelines. However, when installing a pump complete with

Strany 10 - LTRS/REV.)

Page 17 3.4 Start Up Procedure. - Check that all piping and associated equipment are clean and free from debris and that all pipe connection

Strany 11

Page 18 - Ensure product is available in the tank before starting pump. This is very important for pumps installed with unflushed product seals, as t

Strany 13 - Page 12

Page 19 Where heating/cooling devices are employed, the heating/cooling media should be circulated 15-20 minutes prior to pump start-up and should be

Strany 14 - Page 13

Page 20 3.8 Integral Pressure Relief Valve. Integral pressure relief valves are normally used to protect the pump from the effects of increases in

Strany 15 - Page 14

Page 21 Fig 9 Pre-Set Relief Valve. ITEM NUMBER DESCRIPTION 101 RV FRONT COVER 103 DIAPHRAGM (PTFE FACE TO THE PR

Strany 16 - Page 15

Page 22 4.0 RTPTM Pump Dismantling and Assembly. Before undertaking any work on the pump the Shutdown Procedure should be followed in section 3.5, an

Strany 17 - Page 16

Page 23 4.1 Disassembly. 4.1.1 Front Cover and Rotor Removal see Fig 10. - Follow recommended Shutdown Procedure, referring to section 3.5. -

Strany 18 - Page 17

Page 24 4.1.2 Gearbox Dismantling (After Completing 4.1.1). The following procedures assume that pump has been removed from the baseplate and that th

Strany 19 - Page 18

Page 25 - Remove shaft assemblies from the gearbox (16, see fig 5.6). Shaft assemblies will be complete with gears (14), and bearings (24 and 19) – s

Strany 20

Page 26 4.1.3 Shaft Disassembly. - Remove the rear bearing assembly (19). - Remove the timing gear screws (23). - Remove the timing gear (14) an

Strany 21 - Page 20

Page 27 4.2 Assembly. 4.2.1 Gearbox & Rotorcase Assembly, see fig 14. - Install front bearing cups (24 not shown). Do not install the fro

Strany 22 - ITEM NUMBER DESCRIPTION

Page 28 4.2.2 Shaft Assembly – RTP20 - Install front bearing (24) to shaft (9 or 10). - Install o-rings (26 and 25), to shafts (9 or 10) in the

Strany 23 - Page 22

Page 2 INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR RTPTM ROTARY LOBE PUMPS. 11..00 SSAAFFEETTYY IINNFFOORRMMAATTIIOONN.. 44 11..11 RRIISSKK

Strany 24 - Page 23

Page 29 4.2.3 Shaft Assembly – RTP30 - Install front bearing (24) to shaft (9 or 10). - Install o-rings (26 and 25), to shafts (9 or 10) in the a

Strany 25 - Fig 11 Endplate Removal

Page 30 4.2.4 Timing. - Rotate the shafts (9 and 10) so as to position the gaps made by the missing splines, in the vertically uppermost position, s

Strany 26 - Gearbox Jacking Point

Page 31 Fig 17 Aligning the mesh point. - Remove the shaft assemblies from the gearbox (16). - Using the holes provided drill and ream both gear

Strany 27 - Page 26

Page 32 4.2.5 Setting the rolling torque. It is important that the product seals and both front and rear lip seals are not installed until the beari

Strany 28 - see fig 14

Page 33 4.3 Product Seal Fitting and Removal. 4.3.1 General Procedures for Installing Seals. - Mechanical seals are precision-engineered assembli

Strany 29 - Page 28

Page 34 i) Terminology. a) "Quench" - To provide a liquid barrier, which is not, induced to flow through the seal area by any external me

Strany 30 - Page 29

Page 35 4.3.2 RTP20 O-Ring Seal. Fig 22 O-Ring Seal Cartridge. Read the general procedures before proceeding, refer to sectio

Strany 31 - Page 30

Page 36 4.3.3 RTP30 Class 1 Hygienic Mechanical Seal. Fig 19 Class 1 Hygienic Mechanical Seal. Read the general procedures before proceeding, refe

Strany 32 - Page 31

Page 37 4.3.4 RTP30 Class 2 Hygienic Mechanical Seal. Fig 20 Class 2 Hygienic Mechanical Seal. Read the general procedures before proceeding, refe

Strany 33

Page 38 4.3.5 RTP30 Standard Radial Lip Seal. Fig 21 Standard Radial Lip Seal Cartridge. Read the general procedures before proceeding, refer to s

Strany 34 - Page 33

Page 3 44..33 PPRROODDUUCCTT SSEEAALL FFIITTTTIINNGG AANNDD RREEMMOOVVAALL.. 3333 44..33..11 GGEENNEERRAALL PPRROOCCEEDDUURREESS FFOORR IINN

Strany 35 - Page 34

Page 39 4.3.6 RTP30 O-Ring Seal. Fig 22 O-Ring Seal Cartridge. Read the general procedures before proceeding, refer to section 4.3.1. - Remove

Strany 36 - Page 35

Page 40 5.0 Specifications. 5.1 Clearance Chart A B C D Millimetres 0.30 – 0.50 0.25 – 0.50 0.45 – 0.65 0.25 – 0.40 RTP2

Strany 37 - Page 36

Page 41 5.2 Fasteners & Torque Settings. ITEM DESCRIPTION POSITION RTP20 RTP30 2 Socket He

Strany 38 - Page 37

Page 42 5.3 Lubricants. The recommended synthetic gearbox grease for use in the RTPTM is one that is intended for ‘sealed for life’ units. Suitable f

Strany 39 - Page 38

Page 43 5.4 Tool List. Listed below are tools required for the maintenance of the RTPTM pump. RTP20 TYPE SIZE OR RANGE HEXAGON (ALLEN) KEY 3 MM

Strany 40 - Page 39

Page 44 BB100 mm or 4" PORT80 mm or 3" PORT 5.5 RRTTPP3300 FFoouunnddaattiioonn DDiimmeennssiioonnss –– SSttuubb SShhaafftt DDrri

Strany 41 - A B C D

Page 45 BBECDTSAQMPRNLHBHTHSXXVW4 HOLES 'U' DIACONNECTION SIZE 5.5.1 RTP20 and 30 Foundation Dimensions – Basic Pump (Hydraulic Drive)

Strany 42 - Page 41

Page 46 Dimensions in millimetres Dimensions in Inches A B1 B2 B3 B4 B5 C D E HB HS HT L M N P Q R S T U V W X Wei

Strany 43 - Page 42

Page 47 5.6 Typical Basic Pump Build

Strany 44 - OR RANGE

Page 48 5.7 Trouble Shooting. NO FLOW IRREGULAR FLOW UNDER CAPACITY PUMP OVERHEATS MOTOR OVERHEATS EXCESSIVE ROTOR WEAR EXCESSIVE SEAL WEAR NOISE

Strany 45 - 3" PORT

Page 4 1.0 Safety Information. INCORRECT INSTALLATION, OPERATION, OR MAINTENANCE OF EQUIPMENT MAY CAUSE SEVERE PERSONAL INJURY OR DEATH AND/OR EQUIPM

Strany 46

Page 49 5.8 RTPTM Service History. Pump Serial No: Date Comments

Strany 47

Page 50 5.9 Notes. The information contained in this document is correct at time of print, but may be subject t

Strany 48 - Page 47

Page 51 Johnson Pump (UK) Ltd. O A unit of IDEX Corporation Highfield Industrial Estate, Edi

Strany 49 - 5.7 Trouble Shooting

Page 5 The mounting of the pump or pump unit should be solid and stable. Pump orientation must be considered in relation to drainage requirements. O

Strany 50 - Pump Serial No:

Page 6 DO NOT attempt any maintenance or disassembly of the pump or pump unit without first ensuring that: - The pump is fully isolated from the po

Strany 51

Page 7 1.1 Risk assessment relating to the use of Johnson Pump (UK) Ltd. RTP rotary lobe pumps and pump units in potentially explosive atmospheres.

Strany 52

Page 8 2.0 Introduction. 2.1 General. RTPTM rotary lobe pump is manufactured by Johnson Pump (UK) Ltd. a subsidiary of Viking Pump Inc., Cedar Fal

Komentáře k této Příručce

Žádné komentáře