G. Door Strike Relay Wiring
Use the relay contacts of the Master module to activate door strikes, magnetic locks, and gate controls. Normally
closed, normally open and common contacts are provided for both entry locations.
* Note: Gate controllers do
not typically require power.
Doorstrike 1
3
4
5
Normally Open
Common
Normally Closed
Doorstrike 2
6
7
8
Normally Open
Common
Normally Closed
P
P
r
r
o
o
g
g
r
r
a
a
m
m
m
m
i
i
n
n
g
g
A. Definitions
Program Phone: A single line telephone or buttset connected to the Program Phone port (RJ-11) of a C-3000 module.
Building Manager's Programming Phone: A single line telephone or buttset connected to pins 25/50 so that the Building Manger
may easily change keyless entry codes, without the necessity of travelling to the C-3000 system.
Tenant Keyless Entry code: A four to six-digit code assigned to a tenant, which is used to gain access to the building through the
C-3000 system. Keyless entry codes are programmed into memory positions #01-#96. There are no factory default settings for these
values, nor is it a requirement that they be set.
Master Keyless Entry Code: A single four to six-digit code, which is normally not assigned to a tenant, but may be made known to
the building manager, maintenance or security personnel. The Master keyless entry code is programmed into memory position #00.
There is no factory default setting for this value, nor is there a requirement that it be set.
Relay Activation Time: The period of time (in seconds) for which a C-3000 door strike relay will remain activated, after having been
given an activation code. This value is factory preset to (5) seconds.
Relay Activation Code: The one-digit code entered on a tenant's touch-tone telephone keypad, which will activate a door strike
relay to allow a visitor access to the building. This code is factory preset to "6".
Maximum Call Time: The maximum time (in minutes) allowed for a single conversation between a visitor at the door phone and a
tenant. If this time is exceeded, both parties will be disconnected. This value is factory preset to (2) minutes.
Maximum Ring Count: The maximum number of times the C-3000 system will ring any tenant's telephone, after being activated by
a visitor at the door phone. This value is factory preset to (7) rings.
Number of Modules: The sum total of C-3000 modules in the C-3000 system. This value is factory preset to (1).
B. Quick Programming Guide
Master Module Set Up
Number of modules (1-8, factory set to 1) ...................................................................
Master keyless entry code (4-6 digits, no digits disables) ............................................
Tenants keyless entry codes (4-6 digits, no digits disables) ........................................
Clear all keyless entry codes and set all programming features to factory settings .....
Slave and Master Module Set Up
Relay activation time (0-9, factory set to 5 sec, 0=.5 sec) ............................................
Relay activation code (factory set to 6) (cannot be a # or a Q) (no digit=disable) .........
Maximum entry phone time (0-9, factory set to 2 min, 0=disabled) .............................
Maximum ring count (0-9, factory set to 7, 0=10) .......................................................